⚠ EU DoC & Technical Manual Audit Alert — TESVOLT TS HV 70 (v.A.02 · rev. 11/2019 · 43 pp., PDF pp. 7–8, 11, 38–40, 42):
  1. Repealed Directive 2006/66/EC & Missing EU DoC / Reg. (EU) 2023/1542 (p. 11): Lists repealed Directive 2006/66/EC (German Batteries Act BattG), omits Regulation (EU) 2023/1542 entirely, and cites CE, UN 38.3, IEC 62619, IEC 61000-6-1/2/3/4 without edition years, a signed EU DoC ID/link, or test reports.
  2. Germany-Only Take-Back, Weight Residual & Voltage/Fire-Safety Checks (pp. 7–8, 11, 42): Free GRS take-back covers Germany only (Art. 74(1) needs EU-wide coverage); 14→16 module weight jumps 74 kg (824 → 898 kg) vs. 2 × 36 kg = 72 kg (~80–82 kg unexplained residuals); 666–930 V DC is not split per variant; and Class D metal extinguisher guidance (pp. 7–8) needs confirmation for Li-ion NMC.
  3. Missing Identity, Material, Performance & BMS Data (pp. 6–7, 11, 38–40): No ISO/IEC 15459 / GS1 ID, passport registrant, plant/date, serial format, hazardous substances, CRMs (>0.1%), renewable content, anode/electrolyte, storage temperature, cycle-life test standard, internal resistance, RTE at 50% life, or exploded dismantling drawings; BatMon logs SoC/SoH and kWh throughput rather than Annex XIII item-level Ah, power, RTE, self-discharge, or ohmic resistance.
EU DIGITAL BATTERY PASSPORTReg. (EU) 2023/1542 · Art. 77 · Annex XIII
BRAND / OEM

TESVOLT GmbH

Unique Identifier (ISO/IEC 15459 · GS1 Digital Link)
Economic operator
EU DPP Registry: Pre-Registration Diagnostic Staging — Mandate: 18 Feb 2027 ·
Aligned with EC Guidance v3.2 (19 Oct 2026) · BatteryPass-Ready v2.0 · Audit date

Diagnostic Readiness Scorebar

Demonstrator only. Gates are simulated; no real eIDAS or customs authentication. Audited from RDTI002EENGInstallationManualTSHV70vA02.pdf (rev. 11/2019, 43 pp.). Scope: TESVOLT TS HV 70 battery modules (4.8-1C-HV1000) & APU HV1000-S (excludes third-party SMA STPS 60 inverter).